The images in this article were generated with artificial intelligence. How we publish
Researchers of the firm Binarly have confirmed that a prior correction of Zyxel for the GS1900 switches did not completely block an exploited vulnerability in real environments, and Zyxel published on October 23 a new patch (2.90 Patch 3) that, according to the supplier and the researchers, corrects the gap that continued to allow remote execution of commands without authentication. The practical magnitude: any actor with access to the switch management web interface could run commands with root privileges.
What happened (confirmed facts). In June Zyxel published an update (2.90 Patch 2) to mitigate an initially registered vulnerability as CVE-2026-7273. Binarly subsequently reported to Zyxel on September 29 that, despite this correction, there was another failure that allowed to circumvent the protection added by Patch 2; Zyxel published on October 23 the Patch 3 for 10 GS1900 models and described additional corrections that the manufacturer attributed to a different failure, now traced as CVE-2026-107441. The US Government. USA (CISA) added CVE-2026-7273 to its Known Exploited Vulnerabilities (KEV) catalogue on September 21 and gave emergency deadlines to apply Patch 2. Meanwhile, GreyNoise detected attack traffic that, according to his analysis, committed 996 switches around August 17 and reported that 564 of these devices used credentials by default.

How the failure works technically (confirmed by technical analysis). The switch web service stores request parameters in a fixed area designed for up to 140 entries. The explosion takes advantage of a out-of-line writing (out-of-bounds write): sends an excessive size number 140 parameter that overwrites the internal parameter counter, and then an additional parameter that is written outside the intended area, rewriting function points. This method replaces the function that the process was to invoke by one that executes an attacker command. Patch 2 added a check of the counter, but the check is done after copying the parameter too large, so the counter has already been manipulated and the explosion continues to work. Patch 3, according to Zyxel and Binarly, checks the counter before the copy and limits the size of the parameters, closing the described operating route.
Who it affects (confirmed and estimated). It affects the Zyxel GS1900 series whose devices are accessible by the web management interface and which run firmware in Patch 2 or earlier versions; the models for which Zyxel published Patch 3 must be updated to the specific building of its model. GreyNoise observed large-scale commitments in August in hundreds of units, so exploitation in the real world is not just theoretical. The vector is "network reach" to the management port: if a computer can reach the switch web interface, it is exposed.
Actual and risk implications (confirmed and assessed). The explosion allows the execution of commands with root privileges, which allows from the exfiltration of configurations and hashes of credentials to the installation of backdoors that persist after rebeginnings. GreyNoise documented that the attackers downloaded a data collection script and left the results ready to collect; the information taken included switch settings, root account hashes and network data. This facilitates side movements, VLans theft, malicious reconfiguration or support point for wider campaigns. The presence of large amounts of devices with default credentials increases the actual impact.
What is known with uncertainty. It is not publicly confirmed if all the incidents detected in August exploited exactly the same fault that Patch 3 corrects; Binarly offers two hypotheses: either Patch 2 was an incomplete correction (a faulty "fix") for the same problem, or the attackers used another vulnerability that CISA had not listed. Zyxel has not publicly stated whether the new CVE-2026-107441 was exploited in these incidents. There is also no official confirmation of whether to apply Patch 3 eliminates persistent access that an attacker has already installed in a switch; in general, a patch corrects vulnerability but does not remove a previously installed backdoor.
What managers and owners should do now (concrete and verifiable measures). 1) Update immediately to the firmware 2.90 Patch 3 corresponding to your GS1900 model. Download the specific build from the Zyxel support site and check for sums / signatures if they are available before applying the update. Backup the configuration and schedule a maintenance window. See the official list of building and version notes on the manufacturer's support web: https: / / support.zyxel.com.
2) If you cannot update immediately, isolate the management interface: move management to an off-band management network, apply access control lists that limit authorized IPs, close web access from unreliable networks, or block management ports on the firewall. Disable unnecessary management services (HTTP, Telnet) and use only secure and authenticated protocols.
3) Change all the default credentials and implement strong password policies and key rotation. GreyNoise reported a significant number of devices with default credentials; correcting this reduces the immediate risk of automated attacks.
4) Verify Engagement Indicators (confirm and act): look for scripts or unusual files stored in the switch, unknown command outputs, outgoing connections to external servers and unauthorized configuration changes. If you suspect commitment, capture images of the memory / state of the device before updating, and consider a complete rearrangement or factory restoration after extracting devices for forensic analysis.

5) Monitor traffic and scanning: implement detection of outgoing connections from managed switches and seek communication signs with command and control servers. Telemetry tools and services such as GreyNoise can help correlate suspicious activity; see public intelligence resources such as the catalogue of vulnerabilities exploited by CISA: https: / / www.cisa.gov / knowledge-exploited-vulnerabilities-catalog and analysis of researchers in independent suppliers (e.g. Binarly and GreyNoise: https: / / binarly.io, https: / / www.greynoise.io).
Final operational recommendation (practical and prioritized). Prioritize the updating of any GS1900 switch accessible from unreliable networks. If a switch has already been public or in exposed VLans, treat the team as committed to the contrary: capture evidence, rearrange from a reliable image and restore well-known configurations from validated backups. In the medium term, implement network segmentation to separate management plans, apply device hardening and register changes centrally to detect future intrusions.
Conclusion. The situation underlines that a patch can remedy technical vulnerability and, however, remains incomplete in the face of operating variants; the transfer of responsibility rests with managers: update firmware, reduce management interface exposure and verify device integrity are concrete and urgent steps to mitigate this risk.
Related
More news on the same subject.

Drago detects prompts exfiltration in three IA suppliers; OpenRouter withdraws three suppliers
This week the research of the firm Dragos revealed a data exfiltration pattern that affected at least three suppliers offering inference of IA models: sustained attacks for mont...

NebuSec reveals chain of exploitation in Muse that could steal chats and user memories
Researchers at the NebuSec security firm demonstrated in the laboratory a chain of exploitation that allowed a malicious website, opened by Meta's personal assistant called Muse...

Meta fixes three WhatsApp vulnerabilities on Android, iOS and Mac; CVE-2026-23871 exposes IP
Meta has patched three vulnerabilities in WhatsApp that affect Android, iOS and Mac customers, including a failure in the Android application that the company itself links to a ...

KVM AMD Vulnerability with nested virtualization allows you to read host memory; patch applied
A vulnerability in KVM, the hyperviewer integrated into the Linux kernel, allowed researchers to read large portions of the physical memory of the host server from within a virt...

ROMULUS delivers a RAT with DLL sideloading and DoH using ClickFix
Security researchers have identified a malware distribution platform called "ROMULUS" which is serving as a delivery point for a remote access Trojan (RAT) so far undocumented, ...

The IA potentiates social engineering attacks and abuse of supplier credentials
The scene is not spectacular: an email that looks like human resources, a service cut-off notification that matches the time you're in a hurry, a pop-up window of an application...

CVE-2026-123890: VMware vmdir authentication bypass; patches available
A critical failure at VMware vCenter allows an attacker with network access to avoid authentication and obtain unauthorized access to the system, according to a notice published...